<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-23 12-38-19
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 4/5, 48 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 76 kHz 3163 22,2257
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,8 dBr 7,47 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 12:38, 23.04.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 3/5 (47 dBuV) Max at: 76 kHz MIN: 5 kHz % above 76 kHz: 22,2257 Acquired: 2025/04/23 12:37:15 Total samples: 3163 Equivalent time: 0:02:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 8,2 dBr MIN: 6,8 dBr AVE: 7,47 dBr % above 10,2 dBr: 0,0 Last value: 7,2 dBr (2025/04/23 12:37:15) Station: 103.10 MHz, signal: 3/5 (48 dBuV) 12:30 12:31 12:32 12:33 12:34 12:35 12:36 12:37 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality